$20.99 $24.99
Kerrison micro ejector rongeur working length 200mm, thin footplate angled up 40º 6.0mm bite 9.0mm opening small handle
- Kerrison rongeur supports controlled bone removal in general surgery and neurosurgery.
- 200mm working length extends reach into deeper operative fields.
- 40° upward angulation helps approach anatomy while preserving working visibility.
- 3mm bite supports focused removal where precision matters.
- T-Bar handle supports controlled handling during repeated rongeur manipulation.
- 8-inch overall length balances useful reach with manageable instrument handling.
$58.50 $65.00
Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide
Full Class I/IIa regulatory compliance and ISO 13485:2016 certification
48–54 HRC Rockwell hardness with anti-glare satin matte finish
Direct 3–5 day tracked delivery across EU, USA and international clinical destinations
Technical Specifications & Procurement Options
SurgiValley Surgical Directorate- European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
- Facility Standard: ISO 13485:2016 quality management system audited manufacturing
- Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
- Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
- Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
- Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
- Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
- Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
- Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
- Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
- Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
- Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
- Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
- International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
- Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
- Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
Manufacturing & Fulfillment Timeline
Clinic Brief & RFQ
Submit requirements or reference catalog numbers. Formal quote in 24 hours.
Sample & Technical File
Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.
Precision Sialkot Forging
Hot drop-forged and hand-finished with 100% tactile inspection.
Tracked Clinic Delivery
DHL Express tracked delivery directly to your clinic or practice door.
OEM & International Cross-Reference Equivalents
| Manufacturer / Benchmark | Catalog Number (REF) | Specification Match |
|---|---|---|
| Innomed | G46-932 | Exact Pattern Match |
| Medline | PF123021 | Exact Pattern Match |
| Nopa | KO 278 | Exact Pattern Match |
| Symmetry Surgical | 31-0503 | Exact Pattern Match |
| Teleflex | 431462 | Exact Pattern Match |
Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.
SKU: 011210856
EMDN (EUDAMED): L091302 (BONE RONGEURS, REUSABLE)
GMDN Code: 35375 (Stopcock)
Controlled Access for Precise Rongeur Work
The Kerrison micro ejector rongeur is designed for controlled removal of small amounts of hard tissue where a narrow working profile and extended reach support access. Its 200mm working length helps the instrument reach deeper operative fields, while the 40° upward angle positions the bite for an elevated approach. The T-bar handle provides a familiar format for controlled manipulation during general surgery and neurosurgery workflows. A 3mm bite supports focused removal rather than broad engagement, helping users work within confined areas while maintaining deliberate instrument placement and handling.
Use Cases
- Remove small amounts of bone or other hard tissue during general surgical procedures requiring a focused rongeur bite.
- Support neurosurgical workflows where extended reach and an upward-angled approach help access confined operative fields.
- Use the 3mm bite for controlled engagement when a narrow removal point is preferred.
- Apply the T-bar handle for steady manipulation during repeated rongeur passes.
- Use the 200mm working length when access beyond the immediate incision or instrument entry point is required.
Specifications
| Bite Size | 3mm |
| Angle & Direction | 40° Up |
| Handle Type | T-Bar |
| Overall Length | 8" |
| Working Length | 200mm |
| Dimensions | 200mm, 6.0mm, 9.0mm |
Care & Handling
- Clean the rongeur promptly after use according to facility protocols and the applicable instructions for use.
- Inspect the 3mm bite, thin working profile, angled tip, and handle before and after use for visible damage, deformation, or impaired movement.
- Handle the working end carefully during transport, cleaning, and storage to help protect the narrow bite and 40° angled profile.
- Store the instrument in a manner that prevents contact damage to the working end and supports ready inspection before use.
General use; follow facility protocols.
| Bite Size | 3mm |
| Angle & Direction | 40° Up |
| Handle Type | T-Bar |
| Overall Length | 8" |
| Working Length | 200mm |
No product reviews yet
Write Your Review
Be the first to review this product
Share relevant product experience to help other buyers make an informed decision.