心脏直视手术器械包

118 Pieces
  • 29件器械支持有序的心脏直视手术准备。
  • 不锈钢结构支持常规处理和再处理工作流程。
  • 多种器械有助于在胸外科手术中保持高效通路。
  • 协调的器械包帮助团队在整个手术准备过程中将关键心血管器械保持在一起。
  • 专为在心血管和胸外科手术环境中的实用操作而设计。
  • 一个支持有序手术就绪性的29件套解决方案。

$245.00 $284.88

Volume Price Breaks (RTS) Factory Direct
1 - 9 pcs
$284.88
Sample Order
10 - 49 pcs
$242.15
-15%
50 - 99 pcs
$213.66
-25%
100+ pcs
$185.17
-35%
Estimated Order Total: $284.88 ($284.88/pc)
Direct Sialkot Surgical Forge & Clinical Manufacturing Assurance
CE MDR & FDA Registered EMDN: L0399 GMDN: 47549
Direct Sialkot Surgical Forge 35–45% procurement savings vs EU/US middlemen
AISI 420 / 440A German Stainless DIN 1.4021 metallurgy, 48–54 HRC, ASTM A967
134°C Autoclave Reusable Steam sterilizable with DIN silicone cassette durability
Low MOQ Hospital & Clinic Sets Custom procedure packs with laser UDI batch traceability
<24h Clinical Spec Review In-house precision tip geometry & sample benchmarking
Quantity
View Quote (0)
(249 products available)
Added to quote! View Quote Cart
Instant WhatsApp Inquiry
🌐
Worldwide, EU & USA Clinic Ready

Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide

📋
CE MDR 2017/745

Full Class I/IIa regulatory compliance and ISO 13485:2016 certification

🔬
AISI 420 German Steel

48–54 HRC Rockwell hardness with anti-glare satin matte finish

✈️
DHL Express Global Delivery

Direct 3–5 day tracked delivery across EU, USA and international clinical destinations

Technical Specifications & Procurement Options

SurgiValley Surgical Directorate
Clinical Quality & Compliance
  • European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
  • Facility Standard: ISO 13485:2016 quality management system audited manufacturing
  • Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
  • Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
Metallurgical Architecture
  • Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
  • Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
  • Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
  • Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
Minor Surgery & Procedure Packs
  • Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
  • Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
  • Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
  • Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
Direct Procurement Economics
  • Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
  • International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
  • Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
  • Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
{-- 4-Step Order Timeline --}
Manufacturing & Fulfillment Timeline
1
Clinic Brief & RFQ

Submit requirements or reference catalog numbers. Formal quote in 24 hours.

2
Sample & Technical File

Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.

3
Precision Sialkot Forging

Hot drop-forged and hand-finished with 100% tactile inspection.

4
Tracked Clinic Delivery

DHL Express tracked delivery directly to your clinic or practice door.

Clinical Regulatory Nomenclature & Standards
UNIVERSAL NOMENCLATURE EU MDR 2017/745 & US FDA GUDID Classification
EMDN (EUDAMED): L0399
GENERAL SURGERY INSTRUMENTS, REUSABLE - OTHER
REUSABLE SURGICAL INSTRUMENTS > GENERAL SURGERY INSTRUMENTS, REUSABLE > GENERAL SURGERY INSTRUMENTS, REUSABLE - OTHER
GMDN Code: 47549
General surgical instrument, reusable

SKU: 090210276

EMDN (EUDAMED): L0399 (GENERAL SURGERY INSTRUMENTS, REUSABLE - OTHER)

GMDN Code: 47549 (General surgical instrument, reusable)

Categories: 心血管与胸外科套装

Tags: 胸外科器械, 心血管手术器械, 心脏手术器械, 开胸心脏手术器械, 胸科手术器械

  • Surgical Knife Handle No#3(2)
  • Surgical Knife Handle No#4(2)
  • Surgical Knife Handle No#7(2)
  • Halsted Mosquito Forceps(8)
  • Crile Artery Forceps(6)
  • Pean Artery Forceps(4)
  • Ochsner Artery Forceps(4)
  • Boettcher Tonsil Art Forceps(2)                 
  • Parsonnet Aorta Clamp(6)                 
  • Lambert-Kay Aorta Clamp(2)                 
  • Collins Intestinal Forceps(2)                 
  • Vanderbilt Deep Vessel Forceps(4)                  
  • Kantrowitz Thoracic Clamp(4)                  
  • Foerster Sponge Forceps(2)                 
  • Backhaus Towel Forceps(4)                 
  • Non-Perf Towel Clamp(4)                 
  • Vital Mayo Dissecting Scissors(2)                 
  • Vital Metzenbaum Dissecting Scissors(2)                 
  • Vital Metzenbaum Scissors(2)                 
  • Vital Castroviejo Needle Holder(1)                
  • Vital DeBakey Cardio Needle(2)                  
  • Vital Mayo-Hegar Needle Holder(6)                 
  • Vital Microvascular Needle Holder(2)                
  • Adson Forceps, 1×2 Teeth(2)                 
  • Bonney Tissue Forceps(2)                 
  • Cooley Vascular Tissue Forceps(2)                 
  • DeBakey-Dietrich Tissue Forceps(4)                 
  • Dressing Forceps(2)                 
  • DeBakey-Bahnson Curved Clamp(2)                 
  • DeBakey Satinsky Clamp(4)                  
  • DeBakey Multipurpose Clamp(2)                
  • Cooley Partial Occlusion Clamp(4)                
  • Cooley Multi-Purpose Clamp(2)                 
  • Cooley Anastomosis Clamp(2)                  
  • Vital Wire Cutter(2)                 
  • Tissue Forceps(4)                
  • Richardson Retractor(4)                 
  • Tube Suction Yank Auer(2)                 
  • Pool Abdominal Suction Tube(1)                 
  • Tube Suction Adson(1)               
  • USA Retractor(1)   

适用于心血管、胸外科和耳鼻喉科手术的实用29件套器械包

当心血管、胸外科及相关耳鼻喉科手术需要在手术区域配备多种器械时,这款29件套手术器械包提供了一种实用、整合的解决方案。该不锈钢器械套件支持常规任务,如暴露、组织处理、剥离和手术通路,无需从多个器械包中单独挑选每一种器械。其心脏直视和胸外科定位使其成为专业外科环境中的实用选择,在这些环境中,有序的准备和可靠的操作非常重要。请根据每种器械的预期功能和机构既定规程使用。

使用场景

  • 在心脏直视和胸外科手术中支持暴露和通路。
  • 使用适合任务的器械进行受控的软组织处理和剥离。
  • 在倾向于使用整合器械选择的心血管和胸外科手术准备中提供协助。
  • 在专业外科环境中为相关耳鼻喉科手术提供器械选择。
  • 在无菌区组织常用器械,以实现高效的手术工作流程。

规格

件数29件
材质不锈钢

护理与处理

  • 使用后根据机构规程和适用的制造商说明,及时清洁和处理器械。
  • 在使用前后检查每件器械的清洁度、对齐情况、表面状况和功能是否正常。
  • 在运输、清洁和储存过程中小心操作器械,以防损坏并保持其工作状态。
  • 遵循适用的IFU和经验证的机构规程进行去污、灭菌、润滑和储存。

一般用途;请遵循机构规程。


3.8
5 Product Reviews
✓ Well Reviewed - 60%
60% rated this product positively
Rating breakdown
5★
3 60.0%
4★
0 0.0%
3★
1 20.0%
2★
0 0.0%
1★
1 20.0%
Write Your Review
Please login to write a review!
Product Reviews 5
E
E. Johnson
3.0
Verified Purchase General Surgery
Feb 15, 2026 (9 个月前)
The instrument set trays we used in the last month have performed adequately during various procedures, including laparotomy and hernia repairs. The balanced weight has made them easy to handle, and the secure locking mechanism provides some reassurance during critical moments of surgery. However, I did notice that the tips, while designed to be atraumatic, could sometimes slip when working close to delicate tissue planes, which raises concerns about potential trauma. Throughout 12 cases, I experienced a couple of instances where the trays did not hold the instruments securely, leading to a minor inconvenience during the setup phase. Overall, while they serve a functional purpose, I believe there is room for improvement, particularly regarding the grip and durability of the materials used, especially for more intensive procedures like bowel resections.
Was this helpful?
E
Emily Johnson, Medical Supply Director
5.0
Verified Purchase General Surgery
Jan 12, 2026 (10 个月前)
The balanced weight and secure locking mechanism improve workflow significantly during laparotomy and bowel resection. A solid addition to our instrument set.
Was this helpful?
E
Emily Johnson, Procurement Manager
1.0
General Surgery
Nov 13, 2025 (1 年前)
I had significant concerns using these instrument holders during recent laparotomy and hernia repair procedures. The lack of a secure locking mechanism meant that instruments would shift unexpectedly, risking contamination and compromising patient safety. I experienced these issues firsthand, performing 12 cases last month, leading to delays and frustration among the surgical team. Additionally, the balanced weight distribution was not as advertised; they felt awkward and cumbersome in hand, impairing my ability for precise blunt dissection and vessel ligation. During an appendectomy, the tips appeared to be inadequately atraumatic, resulting in unnecessary trauma to the tissue plane, which goes against our standard practice for hemostasis. In conclusion, I do not recommend these holders for any surgical setting. They present a significant risk and have not met the essential functional requirements for successful surgical intervention.
Was this helpful?
E
Emily Johnson, Inventory Manager
5.0
Verified Purchase General Surgery
Jul 06, 2025 (1 年前)
These instrument trays have proven to be invaluable during laparotomy and bowel resection. The balanced weight provides excellent handling, while the secure locking mechanism ensures stability during critical moments. The atraumatic tips have significantly improved maneuverability within the tissue planes, allowing for effective blunt dissection without compromising surrounding structures. They were used in 12 cases last month with consistent performance.
Was this helpful?
M
Makenzie Huels
5.0
Verified Purchase General Surgery
Mar 09, 2025 (1 年前)
These instrument trays provide an excellent balance during laparotomy procedures. The secure locking mechanism ensures everything stays in place, enhancing efficiency. Their atraumatic tips offer safety for surrounding tissue layers while performing hernia repairs. Having used them in multiple bowel resections last month, I appreciate the reliability they bring to the workflow.
Was this helpful?