Ferris-Smith laminectomy kerrison rongeur 10 1/2" working length 210mm angled 90º down 4.0mm x 4.0mm bite, finger grip handle

  • Designed for ENT, General Surgery, and Ophthalmic procedures requiring controlled bone removal.
  • 90° down angulation supports access to challenging anatomical working angles.
  • The 210mm working length provides useful reach in deeper operative fields.
  • A 4mm bite enables focused removal while maintaining deliberate instrument control.
  • Angled jaws help approach targeted tissue from a downward direction.
  • Finger grip handle supports secure handling during repetitive rongeur movements.

Brand: surgivalley

$39.00 $45.88

Volume Price Breaks (RTS) Factory Direct
1 - 9 pcs
$45.88
Sample Order
10 - 49 pcs
$39.00
-15%
50 - 99 pcs
$34.41
-25%
100+ pcs
$29.82
-35%
Estimated Order Total: $45.88 ($45.88/pc)
Direct Sialkot Surgical Forge & Clinical Manufacturing Assurance
CE MDR & FDA Registered EMDN: L091302 GMDN: 35375
Direct Sialkot Surgical Forge 35–45% procurement savings vs EU/US middlemen
AISI 420 / 440A German Stainless DIN 1.4021 metallurgy, 48–54 HRC, ASTM A967
134°C Autoclave Reusable Steam sterilizable with DIN silicone cassette durability
Low MOQ Hospital & Clinic Sets Custom procedure packs with laser UDI batch traceability
<24h Clinical Spec Review In-house precision tip geometry & sample benchmarking
Quantidade
(Disponível)
OEM & International Cross-Reference Equivalents
UNIVERSAL NOMENCLATURE EU MDR 2017/745 & US FDA GUDID Classification
EMDN (EUDAMED): L091302
BONE RONGEURS, REUSABLE
REUSABLE SURGICAL INSTRUMENTS > ORTHOPAEDIC AND TRAUMATOLOGICAL SURGERY INSTRUMENTS, REUSABLE > ORTHOPAEDIC SURGERY FORCEPS, REUSABLE > BONE RONGEURS, REUSABLE
GMDN Code: 35375
Stopcock
Manufacturer / Benchmark Catalog Number (REF) Specification Match
Aesculap H26-259-23 Exact Pattern Match
Buxton Biomedical 56-3604 Exact Pattern Match
Katena K7-1802 Exact Pattern Match
Sklar 65-7400 Exact Pattern Match
Teleflex 341836 Exact Pattern Match

Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.

SKU: 011211220

EMDN (EUDAMED): L091302 (BONE RONGEURS, REUSABLE)

GMDN Code: 35375 (Stopcock)

Categorias: Rongeurs Cirúrgicos, Pinças | Instrumentos de punção | Rongeurs, Rongeurs, Instrumentos Lacrimais e Trépanos

Controlled Access and Confident Handling Across Surgical Workflows

The Ferris-Smith laminectomy Kerrison rongeur is a surgical rongeur designed to remove small portions of bone or other firm tissue during procedures requiring controlled nibbling action. Its 210mm working length and 90° down angled profile support access to areas where a longer reach and downward-oriented bite are useful. The 4mm x 4mm bite provides a defined working aperture, while the finger grip handle supports deliberate instrument handling. Suitable for task-focused use across ENT, General Surgery, and Ophthalmic workflows, this specialty-neutral design helps integrate controlled rongeur manipulation into established operative technique and facility protocols.

Use Cases

  • Use for controlled nibbling of bone or firm tissue in laminectomy and other procedures requiring a Kerrison-style rongeur.
  • Use the 90° down orientation to approach target areas from above when a downward-directed bite supports the operative workflow.
  • Apply the 210mm working length when additional reach is useful for accessing deeper or less direct operative sites.
  • Support ENT procedures requiring a compact, angled rongeur profile for controlled tissue or bone removal.
  • Use in General Surgery workflows where a long, angled Kerrison rongeur is appropriate to the procedural task.
  • Include in Ophthalmic instrument workflows only where the procedure and facility protocol call for this rongeur design and 4mm bite.

Specifications

Bite Size4mm
Angle & Direction90° Down
ShapeAngled
Working Length210mm
Dimensions10 1/2", 210mm, 4.0mm
HandleFinger grip

Care & Reprocessing

  • Clean and reprocess the rongeur according to facility protocols and the applicable manufacturer instructions for use.
  • Inspect the jaws, bite edges, hinge, and handle before and after use for damage, alignment issues, or restricted movement.
  • Handle the angled working end carefully during transport, cleaning, and storage to help protect the 4mm x 4mm bite.
  • Store the instrument in a manner that prevents the working end from contacting or damaging other instruments.

General use; follow facility protocols.


Bite Size 4mm
Angle & Direction 90° Down
Shape Angled
Overall Length 210mm
Working Length 210mm
No product reviews yet
Write Your Review
Please login to write a review!

Be the first to review this product

Share relevant product experience to help other buyers make an informed decision.

Help other buyers understand the product