$32.00 $35.63
Pinça Ferris-Smith Kerrison comprimento de trabalho 280mm angulada para cima 40º mordida 3.0mm, cabo ergonômico em anel
- Cabo ergonômico em anel suporta o manuseio controlado do instrumento.
- O ângulo ascendente de 40° melhora o acesso através de uma abordagem alinhada.
- Uma mordida de 3.0mm permite a remoção focada de tecido durante os procedimentos.
- O comprimento de trabalho de 280mm ajuda a alcançar áreas operatórias mais profundas, mantendo um posicionamento confortável da mão.
- A configuração Ferris-Smith suporta a manipulação precisa da pinça Kerrison durante a cirurgia geral.
- Mandíbulas anguladas suportam o controle de mordida direcionado.
$49.50 $55.00
Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide
Full Class I/IIa regulatory compliance and ISO 13485:2016 certification
48–54 HRC Rockwell hardness with anti-glare satin matte finish
Direct 3–5 day tracked delivery across EU, USA and international clinical destinations
Technical Specifications & Procurement Options
SurgiValley Surgical Directorate- European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
- Facility Standard: ISO 13485:2016 quality management system audited manufacturing
- Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
- Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
- Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
- Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
- Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
- Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
- Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
- Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
- Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
- Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
- Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
- International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
- Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
- Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
Manufacturing & Fulfillment Timeline
Clinic Brief & RFQ
Submit requirements or reference catalog numbers. Formal quote in 24 hours.
Sample & Technical File
Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.
Precision Sialkot Forging
Hot drop-forged and hand-finished with 100% tactile inspection.
Tracked Clinic Delivery
DHL Express tracked delivery directly to your clinic or practice door.
OEM & International Cross-Reference Equivalents
| Manufacturer / Benchmark | Catalog Number (REF) | Specification Match |
|---|---|---|
| Medline | PF188595 | Exact Pattern Match |
Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.
SKU: 011210021
EMDN (EUDAMED): L091302 (BONE RONGEURS, REUSABLE)
GMDN Code: 35375 (Stopcock)
Categorias: Conjuntos para Cirurgia Geral, Rongeurs Cirúrgicos, Rongeurs
Controle Kerrison de Longo Alcance para Remoção Óssea Focada
A pinça Ferris-Smith Kerrison é projetada para o desbaste controlado e remoção de pequenas quantidades de osso durante procedimentos cirúrgicos gerais. Seu comprimento de trabalho de 280mm ajuda a estender o acesso a campos operatórios mais profundos ou confinados, enquanto o ângulo ascendente de 40º suporta uma abordagem mais direta quando o alvo não está alinhado com a mão. A mordida de 3.0mm é adequada para trabalhos focados em tecido e osso, e o cabo ergonômico em anel promove uma pegada estável e familiar durante a manipulação repetida do instrumento. Juntas, essas características proporcionam alcance prático, controle direcional e manuseio preciso em condições exigentes de acesso cirúrgico.
Casos de Uso
- Remoção controlada de pequenas quantidades de osso onde uma mordida focada de 3.0mm é apropriada
- Acesso a campos operatórios mais profundos ou confinados com o comprimento de trabalho de 280mm
- Abordagem de alvos de uma direção ascendente usando o perfil angulado de 40º
- Realização de manipulação repetida da pinça com uma pegada familiar de cabo ergonômico em anel
Especificações
| Dimensões | 280mm, 3.0mm |
Cuidado e Manuseio
- Limpar e processar o instrumento de acordo com o procedimento validado de cuidado de instrumentos da instituição e as IFU do fabricante.
- Inspecionar as mandíbulas, a dobradiça, o alinhamento da mordida e o movimento do cabo antes e depois do uso; manusear a extremidade de trabalho cuidadosamente durante a limpeza, transporte e armazenamento.
Uso geral; seguir os protocolos da instituição.
No product reviews yet
Write Your Review
Be the first to review this product
Share relevant product experience to help other buyers make an informed decision.