Dissecador Mixter 10mm Ergo Grip Lavável

  • A mandíbula de 10mm suporta a dissecção controlada de tecidos.
  • A pegada ergonômica promove o manuseio confortável durante procedimentos prolongados.
  • O design lavável suporta fluxos de trabalho eficientes de limpeza pós-uso do instrumento.
  • A configuração do dissecador Mixter suporta o manuseio preciso na dissecção de tecidos em cirurgia geral.
  • O tamanho da mandíbula de 10mm equilibra o acesso com o engajamento proposital dos tecidos.
  • A pegada ergo ajuda a manter o controle de manuseio.

Brand: surgivalley

$15.57 $18.00
Volume Price Breaks (RTS) Factory Direct
1 - 9 pcs
$18.00
Sample Order
10 - 49 pcs
$15.30
-15%
50 - 99 pcs
$13.50
-25%
100+ pcs
$11.70
-35%
Estimated Order Total: $18.00 ($18.00/pc)
Direct Sialkot Surgical Forge & Clinical Manufacturing Assurance
CE MDR & FDA Registered
Direct Sialkot Surgical Forge 35–45% procurement savings vs EU/US middlemen
AISI 420 / 440A German Stainless DIN 1.4021 metallurgy, 48–54 HRC, ASTM A967
134°C Autoclave Reusable Steam sterilizable with DIN silicone cassette durability
Low MOQ Hospital & Clinic Sets Custom procedure packs with laser UDI batch traceability
<24h Clinical Spec Review In-house precision tip geometry & sample benchmarking
Quantidade
View Quote (0)
(250 produtos disponíveis)
Added to quote! View Quote Cart
Instant WhatsApp Inquiry
🌐
Worldwide, EU & USA Clinic Ready

Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide

📋
CE MDR 2017/745

Full Class I/IIa regulatory compliance and ISO 13485:2016 certification

🔬
AISI 420 German Steel

48–54 HRC Rockwell hardness with anti-glare satin matte finish

✈️
DHL Express Global Delivery

Direct 3–5 day tracked delivery across EU, USA and international clinical destinations

Technical Specifications & Procurement Options

SurgiValley Surgical Directorate
Clinical Quality & Compliance
  • European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
  • Facility Standard: ISO 13485:2016 quality management system audited manufacturing
  • Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
  • Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
Metallurgical Architecture
  • Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
  • Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
  • Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
  • Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
Minor Surgery & Procedure Packs
  • Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
  • Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
  • Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
  • Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
Direct Procurement Economics
  • Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
  • International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
  • Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
  • Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
{-- 4-Step Order Timeline --}
Manufacturing & Fulfillment Timeline
1
Clinic Brief & RFQ

Submit requirements or reference catalog numbers. Formal quote in 24 hours.

2
Sample & Technical File

Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.

3
Precision Sialkot Forging

Hot drop-forged and hand-finished with 100% tactile inspection.

4
Tracked Clinic Delivery

DHL Express tracked delivery directly to your clinic or practice door.

Clinical Regulatory Nomenclature & Standards
UNIVERSAL NOMENCLATURE EU MDR 2017/745 & US FDA GUDID Classification
EMDN (EUDAMED): L0315
GENERAL SURGERY DISSECTORS, REUSABLE
REUSABLE SURGICAL INSTRUMENTS > GENERAL SURGERY INSTRUMENTS, REUSABLE > GENERAL SURGERY DISSECTORS, REUSABLE
GMDN Code: 11290
Open-surgery dissector

Dissecção Controlada com Manuseio Ergonômico

O Dissecador Mixter 10mm Ergo Grip Lavável é um instrumento de cirurgia geral projetado para dissecção e manipulação controlada de tecidos. Sua configuração de dissecador Mixter suporta trabalho focado em espaços onde uma abordagem segura e deliberada é importante, enquanto a designação Ergo Grip reflete uma configuração de cabo destinada a suportar o manuseio prático do instrumento durante procedimentos prolongados. O design lavável fornece um caminho para o acesso à limpeza dentro do instrumento. Com um tamanho de mandíbula de 10mm, oferece uma dimensão de trabalho claramente definida para tarefas que exigem agarrar, espalhar ou dissecar de forma medida. Juntas, essas características fornecem uma opção construída especificamente para fluxos de trabalho cirúrgicos organizados e práticos.

Casos de Uso

  • Dissecar e separar tecidos durante procedimentos de cirurgia geral.
  • Manipular tecidos ou estruturas com o tamanho de mandíbula definido de 10mm.
  • Trabalhar de maneira controlada onde um dissecador estilo Mixter é apropriado.
  • Usar a configuração Ergo Grip para o manuseio prático do instrumento durante tarefas procedimentais.
  • Seguir fluxos de trabalho de reprocessamento da instalação que fazem uso do design lavável do instrumento.

Especificações

Revestimento/MaterialAço Inoxidável Alemão AISI 420

Cuidados & Reprocessamento

  • Limpe e reprocesse o instrumento prontamente após o uso de acordo com os protocolos da instalação e as instruções de uso aplicáveis.
  • Use o design lavável conforme indicado pelas instruções de reprocessamento aplicáveis, garantindo que os caminhos internos recebam atenção adequada de limpeza.
  • Inspete as mandíbulas, o cabo e as superfícies acessíveis quanto a sujidades, danos, alinhamento ou movimento prejudicado antes da reutilização.
  • Manuseie e armazene o dissecador de maneira que proteja a extremidade de trabalho e evite danos por contato.

Uso geral; siga os protocolos da instalação.


Jaw Size 10mm
No product reviews yet
Write Your Review
Please login to write a review!

Be the first to review this product

Share relevant product experience to help other buyers make an informed decision.

Help other buyers understand the product