$20.99 $24.99
Sella punch rongeur working length 200mm, thin footplate angled up 40º 1.0mm bite 15.0mm opening medium handle
- 200mm working length provides extended reach for deep surgical sites.
- Angled 40-degree up direction improves visualization around complex anatomical structures.
- Thin footplate design facilitates smooth access within narrow operative corridors.
- 1.0mm bite size enables precise removal of small tissue fragments.
- 15.0mm opening capacity accommodates efficient grasping during various complex procedures.
- Medium handle supports controlled manipulation during neurosurgery and general procedures.
$48.50 $51.05
Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide
Full Class I/IIa regulatory compliance and ISO 13485:2016 certification
48–54 HRC Rockwell hardness with anti-glare satin matte finish
Direct 3–5 day tracked delivery across EU, USA and international clinical destinations
Technical Specifications & Procurement Options
SurgiValley Surgical Directorate- European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
- Facility Standard: ISO 13485:2016 quality management system audited manufacturing
- Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
- Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
- Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
- Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
- Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
- Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
- Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
- Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
- Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
- Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
- Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
- International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
- Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
- Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
Manufacturing & Fulfillment Timeline
Clinic Brief & RFQ
Submit requirements or reference catalog numbers. Formal quote in 24 hours.
Sample & Technical File
Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.
Precision Sialkot Forging
Hot drop-forged and hand-finished with 100% tactile inspection.
Tracked Clinic Delivery
DHL Express tracked delivery directly to your clinic or practice door.
OEM & International Cross-Reference Equivalents
| Manufacturer / Benchmark | Catalog Number (REF) | Specification Match |
|---|---|---|
| Aesculap | FH923B | Exact Pattern Match |
| Buxton Biomedical | 88-6242 | Exact Pattern Match |
| Medline | PF122959 | Exact Pattern Match |
| Symmetry Surgical | NEU-93 | Exact Pattern Match |
| Teleflex | P37327 | Exact Pattern Match |
Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.
SKU: 011211393
EMDN (EUDAMED): L091302 (BONE RONGEURS, REUSABLE)
GMDN Code: 35375 (Stopcock)
Precision Access for Angled Bone Removal
This Sella punch rongeur is designed for precise bone removal in confined anatomical spaces where standard instruments may lack access. Featuring a 40º upward angle and an extra thin footplate, it facilitates visualization and maneuverability during delicate procedures in neurosurgery and general surgery settings. The 1.0mm bite size allows for controlled tissue handling, reducing the risk of collateral damage while the 200mm working length provides necessary reach. This medium handle configuration offers stable grip for detailed work. By combining specific geometry with robust construction, this instrument supports efficient workflow when accessing angled structures or removing small bone fragments without compromising surrounding tissue integrity.
Use Cases
- Removing small bone fragments in confined anatomical spaces
- Accessing upward-angled structures during neurosurgery or general surgery procedures
- Performing precise biting actions with a 1.0mm jaw opening
- Utilizing the 200mm working length for deep tissue reach
Specifications
| Bite Size | 1mm |
| Angle & Direction | 40° Up |
| Shape | Angled |
| Overall Length | 200mm |
| Working Length | 200mm |
| Footplate | Extra Thin |
| Weight Class | Thin Footplate |
| Dimensions | 200mm, 1.0mm, 15.0mm |
Care & Handling
- Clean thoroughly after each use to remove biological debris and prevent corrosion
- Store in a protected environment to maintain the integrity of the thin footplate
- Handle with care to preserve the precise angle and mechanical function
General use; follow facility protocols.
| Bite Size | 1mm |
| Angle & Direction | 40° Up |
| Shape | Angled |
| Overall Length | 200mm |
| Working Length | 200mm |
| Footplate | Extra Thin |
| Weight Class | Thin Footplate |
No product reviews yet
Write Your Review
Be the first to review this product
Share relevant product experience to help other buyers make an informed decision.