$38.00 $41.76
Kilner Needle Holder Finger Rings With Ratchet Suturing Needles Holders
- The ratchet handle helps maintain needle control once the grip is engaged.
- Finger rings provide a familiar interface for precise hand placement.
- Built for suturing needles, the holder supports controlled grasping during closure.
- Ratchet engagement can lessen the need for continuous squeezing during suturing.
- Its finger-ring format supports steady manipulation through routine general-surgery suturing.
- Needle-holder design helps position suturing needles for organized procedural handling.
$20.34 $21.41
Minor surgery packs, dermatology & general instruments for clinics, hospitals & surgery centers worldwide
Full Class I/IIa regulatory compliance and ISO 13485:2016 certification
48–54 HRC Rockwell hardness with anti-glare satin matte finish
Direct 3–5 day tracked delivery across EU, USA and international clinical destinations
Technical Specifications & Procurement Options
SurgiValley Surgical Directorate- European Directive: Full compliance with CE MDR 2017/745 (Medical Device Regulation)
- Facility Standard: ISO 13485:2016 quality management system audited manufacturing
- Class I / IIa Range: Surgical scissors, tissue forceps, needle holders, retractors, scalpel handles
- Worldwide Hospital & Clinic Supply: Approved international procurement standards for hospitals, surgical centers, and private clinics
- Stainless Steel Grade: AISI 420 DIN 1.4021 & AISI 410 surgical grade stainless steel
- Rockwell Hardness: 48–54 HRC vacuum heat-treated for long-term jaw & blade sharpness
- Anti-Reflective Finish: Non-reflective satin matte surface eliminating operating lamp glare
- Passivation Process: ASTM A967 ultrasonic passivation preventing micro-corrosion and pitting
- Procedure Packs: Skin biopsy packs, suture removal, minor surgery, and podiatry sets
- Reprocessing Parameters: Validated for 134°C / 273°F autoclave cycles and automated washer-disinfectors
- Individual Laser UDI: Unique Device Identification and lot numbers etched on every piece
- Packaging Standards: Medical grade peel-pouch sterile or non-sterile bulk with tip protectors
- Factory Direct Pricing: 35–45% procurement savings over European and US distributor list prices
- International Invoicing & Delivery: Fully compliant export invoicing with express 3–5 business day delivery
- Practice Trial Minimums: Flexible 10-pack trial orders for outpatient clinics and day surgery centers
- Replacement Guarantee: Full replacement warranty against any manufacturing or metallurgical defects
Manufacturing & Fulfillment Timeline
Clinic Brief & RFQ
Submit requirements or reference catalog numbers. Formal quote in 24 hours.
Sample & Technical File
Clinical sample kit dispatched in 5–7 days with CE MDR technical declarations.
Precision Sialkot Forging
Hot drop-forged and hand-finished with 100% tactile inspection.
Tracked Clinic Delivery
DHL Express tracked delivery directly to your clinic or practice door.
OEM & International Cross-Reference Equivalents
| Manufacturer / Benchmark | Catalog Number (REF) | Specification Match |
|---|---|---|
| Aesculap | BM211R | Exact Pattern Match |
| Buxton Biomedical | 52-8161 | Exact Pattern Match |
Notice of Nominative Fair Use: All manufacturer names, trademarks, symbols, and catalog part numbers are referenced solely for comparative identification, cross-reference, and equipment compatibility guidance. SurgiValley is an independent surgical manufacturer and is not affiliated with, sponsored by, or endorsed by any of the respective trademark owners.
SKU: 156210003
EMDN (EUDAMED): L0205 (NEEDLE HOLDERS, REUSABLE)
GMDN Code: 12726 (Suturing needle holder, reusable)
Kategorien: Nadelhalter
Controlled Needle Handling for General Surgery Suturing
The Kilner Needle Holder Finger Rings With Ratchet Suturing Needles Holders is a general-surgery instrument for grasping and managing suturing needles during closure and related needle-handling tasks. Its finger-ring design supports familiar instrument positioning, while the ratchet handle provides a way to maintain the selected hold during controlled manipulation. This configuration can help keep the needle holder engaged between movements, supporting an orderly suturing workflow and reducing the need for continuous hand pressure. With its purpose-built needle-holder format, it is suited to professional surgical settings where dependable handling and deliberate needle placement are required.
Use Cases
- Grasping suturing needles during tissue closure in general-surgery procedures.
- Maintaining a controlled hold on a needle while positioning it for passage through tissue.
- Supporting repeated needle handling across interrupted or continuous suturing tasks.
- Using the finger rings for familiar instrument manipulation during suturing workflows.
- Engaging the ratchet when a maintained needle hold is appropriate during handling.
Specifications
| Handle Type | Ratchet |
Care & Reprocessing
- Clean and reprocess the instrument according to facility protocols and the applicable instructions for use.
- Inspect the finger rings, ratchet, and working jaws for visible residue, damage, or impaired movement before use.
- Handle the instrument carefully to protect the needle-holding mechanism and avoid unnecessary impact or misuse.
- Store in a clean, protected location after processing, with the ratchet and working parts handled according to facility procedures.
General use; follow facility protocols.
| Handle Type | Ratchet |
No product reviews yet
Write Your Review
Be the first to review this product
Share relevant product experience to help other buyers make an informed decision.